{"id":1152,"date":"2016-11-01T20:28:47","date_gmt":"2016-11-02T03:28:47","guid":{"rendered":"http:\/\/www.digitalview.com\/blog\/?p=1152"},"modified":"2016-12-16T00:24:18","modified_gmt":"2016-12-16T07:24:18","slug":"ip-60-revisited-network-control-lcd-controllers","status":"publish","type":"post","link":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/","title":{"rendered":"IP-60v2 Commands, Control, Monitoring"},"content":{"rendered":"<p>The IP-50 Ethernet add-on for Digital View LCD controllers was first introduced in 2007\u00a0to provide an Ethernet interface for basic telemetry and the extensive set of controller commands. Since that time it has been enhanced to the current version <a href=\"http:\/\/www.digitalview.com\/accessories\/ip-60v2\" target=\"_blank\">IP-60v2<\/a> to make it faster, add memory and extend its functionality to include more display system monitoring telemetry and system control.<\/p>\n<p>Here are a few specs of the <a href=\"http:\/\/www.digitalview.com\/accessories\/ip-60v2\" target=\"_blank\">IP-60v2<\/a>:<\/p>\n<ul>\n<li>Communication: Ethernet<\/li>\n<li>Connection\u00a0to Digital View LCD controllers: RS-232<\/li>\n<li>Control ports:\n<ul>\n<li>Temperature sensors: 3<\/li>\n<li>Light sensor: 1<\/li>\n<li>Fans: 4<\/li>\n<\/ul>\n<\/li>\n<li>Modes: Web server and direct commands<\/li>\n<li>Power: 5vDC (micro USB)<\/li>\n<li>Size: 77mm x 51mm (3&#8243; x 2&#8243;)<\/li>\n<\/ul>\n<p>The IP-60v2 adds functionality to Digital View controllers such as the ALR-1920 family providing capabilities for functions such as compatibility with AV room controllers and monitoring sensors or fans in outdoor high bright digital signage displays.<\/p>\n<p><a href=\"http:\/\/www.digitalview.com\/blog\/ip-60-revisited-network-control-lcd-controllers\/digital-view-ip-60v2-2\/\" rel=\"attachment wp-att-1156\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1156\" src=\"https:\/\/i0.wp.com\/www.digitalview.com\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1-1024x575.jpg?resize=500%2C281\" alt=\"Digital View IP-60v2 \" width=\"500\" height=\"281\" srcset=\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?resize=1024%2C575&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?resize=300%2C169&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?resize=768%2C431&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?resize=600%2C337&amp;ssl=1 600w, https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?w=1593&amp;ssl=1 1593w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><\/p>\n<p>For more details see <a href=\"http:\/\/www.digitalview.com\/accessories\/ip-60v2\" target=\"_blank\">here<\/a> or <a href=\"http:\/\/www.digitalview.com\/contact-us\" target=\"_blank\">contact Digital View<\/a> or a <a href=\"http:\/\/www.digitalview.com\/resellers\" target=\"_blank\">Reseller<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"mh-excerpt\"><p>The IP-50 Ethernet add-on for Digital View LCD controllers was first introduced in 2007\u00a0to provide an Ethernet interface for basic telemetry and the extensive set of controller commands. Since that time it has been enhanced <a class=\"mh-excerpt-more\" href=\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\" title=\"IP-60v2 Commands, Control, Monitoring\">&#8230; [more]<\/a><\/p>\n<\/div>","protected":false},"author":1,"featured_media":1156,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[3,4],"tags":[],"class_list":{"0":"post-1152","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-digital-signage","8":"category-display-electronics"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>IP-60v2 Commands, Control, Monitoring - Digital View blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IP-60v2 Commands, Control, Monitoring - Digital View blog\" \/>\n<meta property=\"og:description\" content=\"The IP-50 Ethernet add-on for Digital View LCD controllers was first introduced in 2007\u00a0to provide an Ethernet interface for basic telemetry and the extensive set of controller commands. Since that time it has been enhanced ... [more]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\" \/>\n<meta property=\"og:site_name\" content=\"Digital View blog\" \/>\n<meta property=\"article:published_time\" content=\"2016-11-02T03:28:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-12-16T07:24:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"1593\" \/>\n\t<meta property=\"og:image:height\" content=\"895\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"digitalview\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"digitalview\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\"},\"author\":{\"name\":\"digitalview\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/5738f29706ed58f47170e2b73d6699ad\"},\"headline\":\"IP-60v2 Commands, Control, Monitoring\",\"datePublished\":\"2016-11-02T03:28:47+00:00\",\"dateModified\":\"2016-12-16T07:24:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\"},\"wordCount\":156,\"publisher\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1\",\"articleSection\":[\"Digital Signage\",\"LCD Controllers\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\",\"url\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\",\"name\":\"IP-60v2 Commands, Control, Monitoring - Digital View blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1\",\"datePublished\":\"2016-11-02T03:28:47+00:00\",\"dateModified\":\"2016-12-16T07:24:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage\",\"url\":\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1\",\"width\":1593,\"height\":895,\"caption\":\"Digital View IP-60v2\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.digitalview.website\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IP-60v2 Commands, Control, Monitoring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#website\",\"url\":\"https:\/\/www.digitalview.website\/blog\/\",\"name\":\"Digital View blog\",\"description\":\"Digital View LCD controllers\",\"publisher\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.digitalview.website\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#organization\",\"name\":\"Digital View\",\"url\":\"https:\/\/www.digitalview.website\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i2.wp.com\/www.digitalview.com\/blog\/wp-content\/uploads\/2016\/04\/cropped-Digital-View-GRN-Logo-320x132-1.png?fit=320%2C106&ssl=1\",\"contentUrl\":\"https:\/\/i2.wp.com\/www.digitalview.com\/blog\/wp-content\/uploads\/2016\/04\/cropped-Digital-View-GRN-Logo-320x132-1.png?fit=320%2C106&ssl=1\",\"width\":320,\"height\":106,\"caption\":\"Digital View\"},\"image\":{\"@id\":\"https:\/\/www.digitalview.website\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/x.com\/digitalview\",\"http:\/\/digitalview\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/5738f29706ed58f47170e2b73d6699ad\",\"name\":\"digitalview\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2e963c43b49d6d994066b65445d6876c70e1692283c75fc4ed92add363a758bb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2e963c43b49d6d994066b65445d6876c70e1692283c75fc4ed92add363a758bb?s=96&d=mm&r=g\",\"caption\":\"digitalview\"},\"sameAs\":[\"http:\/\/www.digitalview.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IP-60v2 Commands, Control, Monitoring - Digital View blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/","og_locale":"en_US","og_type":"article","og_title":"IP-60v2 Commands, Control, Monitoring - Digital View blog","og_description":"The IP-50 Ethernet add-on for Digital View LCD controllers was first introduced in 2007\u00a0to provide an Ethernet interface for basic telemetry and the extensive set of controller commands. Since that time it has been enhanced ... [more]","og_url":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/","og_site_name":"Digital View blog","article_published_time":"2016-11-02T03:28:47+00:00","article_modified_time":"2016-12-16T07:24:18+00:00","og_image":[{"width":1593,"height":895,"url":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","type":"image\/jpeg"}],"author":"digitalview","twitter_misc":{"Written by":"digitalview","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#article","isPartOf":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/"},"author":{"name":"digitalview","@id":"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/5738f29706ed58f47170e2b73d6699ad"},"headline":"IP-60v2 Commands, Control, Monitoring","datePublished":"2016-11-02T03:28:47+00:00","dateModified":"2016-12-16T07:24:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/"},"wordCount":156,"publisher":{"@id":"https:\/\/www.digitalview.website\/blog\/#organization"},"image":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","articleSection":["Digital Signage","LCD Controllers"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/","url":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/","name":"IP-60v2 Commands, Control, Monitoring - Digital View blog","isPartOf":{"@id":"https:\/\/www.digitalview.website\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage"},"image":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","datePublished":"2016-11-02T03:28:47+00:00","dateModified":"2016-12-16T07:24:18+00:00","breadcrumb":{"@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#primaryimage","url":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","contentUrl":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","width":1593,"height":895,"caption":"Digital View IP-60v2"},{"@type":"BreadcrumbList","@id":"https:\/\/www.digitalview.website\/blog\/ip-60-revisited-network-control-lcd-controllers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.digitalview.website\/blog\/"},{"@type":"ListItem","position":2,"name":"IP-60v2 Commands, Control, Monitoring"}]},{"@type":"WebSite","@id":"https:\/\/www.digitalview.website\/blog\/#website","url":"https:\/\/www.digitalview.website\/blog\/","name":"Digital View blog","description":"Digital View LCD controllers","publisher":{"@id":"https:\/\/www.digitalview.website\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.digitalview.website\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.digitalview.website\/blog\/#organization","name":"Digital View","url":"https:\/\/www.digitalview.website\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.digitalview.website\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/i2.wp.com\/www.digitalview.com\/blog\/wp-content\/uploads\/2016\/04\/cropped-Digital-View-GRN-Logo-320x132-1.png?fit=320%2C106&ssl=1","contentUrl":"https:\/\/i2.wp.com\/www.digitalview.com\/blog\/wp-content\/uploads\/2016\/04\/cropped-Digital-View-GRN-Logo-320x132-1.png?fit=320%2C106&ssl=1","width":320,"height":106,"caption":"Digital View"},"image":{"@id":"https:\/\/www.digitalview.website\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/digitalview","http:\/\/digitalview"]},{"@type":"Person","@id":"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/5738f29706ed58f47170e2b73d6699ad","name":"digitalview","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.digitalview.website\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/2e963c43b49d6d994066b65445d6876c70e1692283c75fc4ed92add363a758bb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2e963c43b49d6d994066b65445d6876c70e1692283c75fc4ed92add363a758bb?s=96&d=mm&r=g","caption":"digitalview"},"sameAs":["http:\/\/www.digitalview.com"]}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/www.digitalview.website\/blog\/wp-content\/uploads\/2016\/11\/Digital-View-IP-60v2-1.jpg?fit=1593%2C895&ssl=1","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p4kCJ1-iA","_links":{"self":[{"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/posts\/1152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/comments?post=1152"}],"version-history":[{"count":11,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/posts\/1152\/revisions"}],"predecessor-version":[{"id":1205,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/posts\/1152\/revisions\/1205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/media\/1156"}],"wp:attachment":[{"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/media?parent=1152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/categories?post=1152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.digitalview.website\/blog\/wp-json\/wp\/v2\/tags?post=1152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}